Ex parte CHU - Page 3




          Appeal No. 97-1403                                                          
          Application No. 08/275,214                                                  


          Noik                          3,184,965           May  25, 1965             
          Guimard et al. (Guimard)      4,455,875           June 26, 1984             
          Mattar, Critical Evaluation and Processing of Data Prior to                 
          Pressure Transient Analysis, Society of Petroleum Engineers,                
          pages 709 through 721, 1992.                                                
               Claims 1 through 3 and 5 through 9 stand rejected under                
          35 U.S.C. § 103 as being unpatentable over Guimard in view of               
          Noik and Mattar.                                                            
               Reference is made to the brief, final rejection and the                
          answer for the respective positions of the appellant and the                
          examiner.                                                                   
                                       OPINION                                        
               We have carefully considered the entire record before us,              
          and we will reverse the obviousness rejection of claims 1 through           
          3 and 5 through 9.                                                          
               We agree with the appellant’s assessment of the teachings of           
          Guimard (Brief, pages 5 and 6), Noik (Brief, page 6), and Mattar            
          (Brief, pages 6 through 8).  The pressure measurement sonde in              
          Guimard uses a pressure and temperature detector 18 in unison               
          with a reference detector 20 that only measures temperature.  By            
          subtracting the temperature reading obtained by detector 20 from            
          the pressure and temperature readings obtained by the detector 18           
          the pressure measurement sonde yields an absolute pressure value            
          of the surrounding medium in the oil well.  The three diaphragms            
                                          3                                           