Appeal No. 96-2838 Application 08/336,721 comparator 97 (Figure 2). The window comparator 97 determines whether selected thresholds have been reached representative of sputtering arc faults. Timer 107 produces an output if two step increases in current (e.g., events) are detected within a selected time period. If two events have occurred within the selected time period, SCR 39 is turned on, energizing trip coil 41 which operates trip mechanism 49 to open contacts 51. Independent claim 13 is reproduced as follows: 13. A circuit breaker for protecting an electrical system from ground faults and sputtering arc faults, comprising current sensing means sensing current flowing in said electrical system; ground fault sensing means connected to said current sensing means and operative to generate a trip signal in response to a ground fault in said electrical system; sputtering arc fault sensing means connected to said current sensing means to generate a trip signal in response to at least two successive step increases in current in said electrical system above a designated magnitude within a selected time interval; and trip means responsive to trip signals generated by said ground fault sensing means and by said sputtering arc sensing means to interrupt current flowing in said electrical system. The references relied on by the Examiner are as follows: Dewey 3,673,455 June 27, 1972 Moser et al. (Moser) 4,402,030 Aug. 30, 1983 Spencer 4,949,214 Aug. 14, 1990 3Page: Previous 1 2 3 4 5 6 7 8 9 10 11 NextLast modified: November 3, 2007