Ex parte DONALDSON - Page 3




          Appeal No. 98-0595                                                           
          Application 08/461,806                                                       

          of disk drives in response to a spindle synchronization                      
          command on said bus, whereby the oscillator assembly connected               
          to said one switch means becomes the master which provides the               
          index signal to all of said plurality of disk drives.                        
                                       Opinion                                         
               The anticipation rejection of claims 1-4 and 9 cannot be                
          sustained.  A reversal of the rejection on appeal should not                 
          be construed as an affirmative indication that the appellant’s               
          claims are patentable over prior art.  We address only the                   
          positions and rationale as set forth by the examiner and on                  
          which the examiner’s rejection of the claims on appeal is                    
          based.                                                                       
               According to claim 1, a plurality of disk drives are                    
          connected to each other by a bus.  Each disk drive includes a                
          means for activating a switch means in response to a spindle                 
          synchronization command on the bus.  An oscillator assembly                  
          activated by the switch means causes the associated disk drive               
          to become a master relative to the other disk drives.  The key               
          to this appeal is the claimed feature of the presence of a                   
          spindle synchronization command on a bus which connects all of               
          the disk drives.                                                             
               The examiner acknowledges that Lewis does not expressly                 
          show a spindle synchronization command on a bus that connects                
                                          3                                            





Page:  Previous  1  2  3  4  5  6  7  8  9  10  Next 