Ex parte PLUMMER - Page 2




          Appeal No. 99-1823                                                          
          Application 08/964,278                                                      


          in the application, as amended by an amendment filed                        
          subsequent to the final rejection.                                          


               Appellant’s invention pertains to a guide structure                    
          (claims 8-14) and method (claims 15-20) for guiding rope into               
          helically wound turns on a capstan, and in particular to a                  
          coupling structure for adjustably fixing the position of the                
          guide structure relative to a support surface of the capstan.               
          As further set forth in the specification, with reference                   
          numerals added for convenience, the coupling structure                      
          comprises                                                                   
               an annular disposition of sockets or coupling                          
               pockets [22] . . . provided on a rear surface of the                   
               guide structure [10].  The coupling pockets receive                    
               a number of somewhat smaller protuberances [24] on                     
               the capstan support structure [1].  As such, the                       
               guide structure can be rotatably indexed to allow                      
               radially adjusting the securement of the guide                         
               structure on the coupling protuberance to variably                     
               fix spacial orientation of the ramped surface [12]                     
               for proper directional feed of the rope [7] onto the                   
               capstan [4].  In the illustrated embodiment, the                       
               protuberances are provided by bolt heads, as                           
               fastening means which maintains the capstan support                    
               structure in assembly.  [Specification, page 3.]                       
               Independent claim 8, a copy of which is found in an                    
          appendix to appellant’s brief, is illustrative of the appealed              

                                         -2-                                          





Page:  Previous  1  2  3  4  5  6  7  8  9  Next 

Last modified: November 3, 2007