Appeal No. 1996-1877 Application No. 08/149,716 soil samples using static headspace analysis, where each soil sample is disposed in a closed vial from the time of collection until sampling and where the closed vial is agitated using Tekmar’s “Optimix” feature while being heated. Mr. O’Neil observes (page 553 of Exhibit Q) that the “Optimix” form of agitation allows the sample to tumble in the vial “so analytes more easily reach the gas/liquid interface, which is required for an extraction to occur,” and resulted in (page 554) a reduction in sample equilibration time from 1.5 hours without vial agitation to 1 hour with appellants’ sample mixing feature. While we are in agreement with the examiner that it would have been prima facie obvious to one of ordinary skill in the art at the time the invention was made to add an agitating step to the method and apparatus of Chlosta so as to gain the advantages thereof noted by the various references relied upon by the examiner (i.e., Fujitsuka and Natelson or Yamano; Greaves and Natelson or Yamano; or Harris and Natelson or Yamano), in route to an ultimate determination of obviousness under 35 U.S.C. 14Page: Previous 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 NextLast modified: November 3, 2007