Appeal No. 1997-1111 Page 13 Application No. 08/105,899 slope of each membership function are varied in dependence on K , K , and K .1 2 3 Accordingly, we find that Ueda meets the claim limitation of calculating fuzzy control parameters of said dynamic process characteristics for tuning said fuzzy logic controller. In addition, as the fuzzy control parameters K , 1 K , and K are outputted from system identification unit 12 to2 3 fuzzy inference unit 11 as tuning variables for controlling the process, we find that Ueda meets the claim limitation of tuning said fuzzy logic controller using fuzzy control parameters for controlling the process. Accordingly, we find that Ueda anticipates claim 1. With respect to claim 14, we additionally find the system identification unit 12 of Ueda to be a tuning module as the system identification unit 12 measures the dynamic process control characteristics and calculates the fuzzy control parameters K , K , and K which1 2 3 tune the process. We therefore find that Ueda anticipates claim 14. Turning now to claims 9 and 10, the examiner’s position (answer, page 4) is that “[a]s per claims 9 and 10 the appellant’s scaling factors and specifically error scalingPage: Previous 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 NextLast modified: November 3, 2007