Appeal No. 2001-2440 Application 09/309,066 element, both of which are integrated into the control circuit (pages 4-5). A control computer distributes to a dosing element adjustment device (20) and a doctor element adjustment device (40) the adjustments required to correct the cross- sectional weight (pages 7 and 9). The examiner argues (answer, page 7): It would further have been obvious that a review of the combination of references in their entirety would suggest that the feedback control pattern of McAleavey could be used with a paper or cardboard web as suggested by ‘183 with an expectation of desirable coating control because McAleavey teaches a feedback control pattern for desirably controlling coating thickness and ‘183 teaches that it is also desirable to use feedback control patterns for controlling coating when coating paper or cardboard webs. In the DE ‘183 feedback control, however, the adjustment devices for the dosing slot and the doctor element are adjusted simultaneously to bring about the desired adjustment of the long wave and short wave coating weight deviations (pages 6-7). Hence, it reasonably appears that if one of ordinary skill in the art, considering DE ‘183, were to apply McAleavey’s method to a paper or cardboard web, that person would use McAleavey’s embodiment wherein, as in the DE ‘183 method, the coating medium pumping rate and the space between the knife and moving web are varied simultaneously (col. 8, lines 61-65). 5Page: Previous 1 2 3 4 5 6 7 8 NextLast modified: November 3, 2007