Appeal No. 2003-0346 Application No. 09/113,925 We reverse each of the aforementioned Section 103 rejections. Our reasons for this determination follow. The subject matter on appeal is directed to a non- destructive evaluation/inspection sensor for detecting or measuring the early stages of corrosion in a metallic structure, which comprises, inter alia, a solid polymer electrolyte membrane and an electrode in electrochemical communication with the solid polymer electrolyte membrane. See claims 1, 33, 39, 47, 51, 53 and 55, together with the specification, page 2, lines 10-11 and page 8, lines 16-18. To detect or measure corrosion in the metallic structure, the solid polymer electrolyte membrane and the electrode must be appropriately arranged so that electro- chemical impedance can be measured upon applying a small AC signal perturbation between the structure and the electrode. See claims 1, 33, 39, 47, 51, 53 and 55, together with the specification, page 8, line 16 to page 15, line 8. Electrical impedance amplitude defines the level of corrosion damage in the structure. See the specification, page 7, together with, e.g., Figures 3 and 4. 3Page: Previous 1 2 3 4 5 6 7 8 9 10 11 NextLast modified: November 3, 2007