(225 ILCS 710/45.43) (from Ch. 96 1/2, par. 4296)
Sec. 45.43. Winzes opening directly from the floor of a drift or stope shall be kept covered by a substantial hatch, or shall be planked over, except when in use, or shall be barred off by a substantial railing not less than 3 1/2 feet nor more than 4 feet above the level of the floor, or shall be provided with a gangway not less than 10 inches wide, which gangway shall have a substantial hand railing not less than 3 1/2 feet nor more than 4 feet above the gangway, and the approaches to such gangway at either end shall be protected by a substantial railing not less than 3 1/2 feet nor more than 4 feet above the floor.
(Source: Laws 1945, p. 1035.)
Sections: Previous 45.36 45.37 45.38 45.39 45.40 45.41 45.42 45.43 45.44 45.45 45.46 45.47 45.48 45.49 45.50 Next
Last modified: February 18, 2015