Sec. 127.097. CONDUCT OF SECOND TEST. (a) The automatic tabulating equipment may not be used to count ballots voted in the election until a test conducted under Section 127.093(c) is successful.
(b) If the initial test is unsuccessful, the presiding judge shall prepare a written record of the changes to the program, adjustments to the equipment, and other actions taken to achieve a successful test. The record shall be retained with the test materials.
(c) When a test is successful, the presiding judge shall certify in writing that a test was successful and the date and hour the test was completed. The certification shall be retained with the test materials.
Acts 1985, 69th Leg., ch. 211, Sec. 1, eff. Jan. 1, 1986.
Section: Previous 127.069 127.091 127.092 127.093 127.094 127.095 127.096 127.097 127.098 127.099 127.100 127.121 127.122 127.123 127.1231 NextLast modified: September 28, 2016