Code of Virginia - Title 45.1 Mines And Mining - Section 45.1-161.131 Misfires

§ 45.1-161.131. Misfires

A. Where misfires occur with electric detonators, a waiting period of at least fifteen minutes shall elapse before a miner shall be allowed to return to the shot area. After such failure, the blasting cable shall be disconnected from the source of power and the battery ends short-circuited before electric connections are examined.

B. Explosives shall be removed by firing a separate charge at least two feet away from, and parallel to, the misfired charge or by washing the stemming and the charge from the borehole with water, or by inserting and firing a new primer after the stemming has been washed out.

C. A very careful search of the working place, and, if necessary, of the coal shall be conducted after the coal reaches the tipple after blasting a misfired hole to recover any undetonated explosive.

D. The handling of a misfired shot shall be directly supervised by the mine foreman or a certified person designated by him.

(Code 1950, § 45-53.7; 1954, c. 191; 1966, c. 594, § 45.1-50; 1994, c. 28.)

Sections:  Previous  45.1-161.124  45.1-161.125  45.1-161.126  45.1-161.127  45.1-161.128  45.1-161.129  45.1-161.130  45.1-161.131  45.1-161.132  45.1-161.133  45.1-161.134  45.1-161.135  45.1-161.136  45.1-161.137  45.1-161.138  Next

Last modified: April 3, 2009