Ex parte CALLAGHAN et al. - Page 8




          Appeal No. 96-2179                                           Page 8           
          Application 07/613,466                                                        
             means 50 for generating                                                    
          pacing pulses at a pacing                                                     
          rate,                                                                         
                                             means 16 for applying                      
                                                electrical stimulus pulses              
                                                to the heart;                           
             means 54 for ascertaining       means 18 for detecting a                   
          the value of a rate-control           cardiac event potential;                
          parameter "RCP",                   means 54 for integrating the               
                                                detected potential over                 
                                                time to obtain a selected               
                                                parameter;                              
             closed-loop control             means 192 for storing said                 
          means 50 for adjusting said           selected parameter;                     
          pacing rate in accordance          means 190 for comparing                    
          with the value of said RCP,           said selected parameter                 
          and                                   with a corresponding                    
                                                selected parameter of at                
                                                least one previous                      
                                                cardiac cycle that has                  
                                                been stored; and                        
                                             means 198 for controlling                  
                                                the rate of said                        
                                                electrical stimulus                     
                                                pulses in response to                   
                                                said comparison.                        
             means 50 for causing said       [25. ...means 190 for                      
          closed-loop control means to             comparing said selected              
          self-adapt to the changes in             parameter with a target              
          value of said RCP which are              value; and                           
          due to factors other than          means 198 for controlling the              
          stress, exercise and heart            rate of said electrical                 
          rate.                                 stimulus pulses in                      
                                                response to said                        
                                                comparison.]                            
               18. A "[c]ardiac pacing apparatus" (Callaghan '900)                      
          would have implied some "means for generating pacing pulses at                