               Hajicek does not teach and would not have suggested a                  
          method meeting any of the defrosting limitations recited in                 
          claims 12 and 13.  The examiner’s reliance on Morissette,                   
          taken alone or in combination with Noda, to overcome this                   
          deficiency is not well founded.                                             


               Morissette discloses a building ventilation system which               
          utilizes a stationary heat recovery core 1, 11 to transfer                  
          heat from exhaust air to fresh air.  In a defrost mode, the                 
          system prevents the intake of fresh air and circulates exhaust              
          air through both the exhaust air path and the normally fresh                
          air path and then back into the building.                                   


               Noda discloses an air conditioner having an aeration                   
          (exhaust) passage 16, a (fresh) air supply passage 18, a total              
          enthalpy heat exchanger 28 for transferring heat from the                   
          aeration air flow to the fresh air flow, an auxiliary aeration              
          heat exchanger 32 in the aeration passage 16 downstream of                  
          heat exchanger 28, and an auxiliary air supply heat exchanger               
          48 in the air supply passage downstream of the heat exchanger               