Appeal No. 2003-0626 Application No. 09/410,896 through a cavity in the cooling chamber housing. See id. pages 3-4. In general, heat conductance to the cooling fluid in the wafer pedestal is less efficient than that provided by cooling fluid in the chamber. Id., page 4, lines 10-12. Due to the difference in cooling rates on the top and bottom surfaces of the wafer, thermal stresses may cause a vertical movement of the wafer from the pedestal resulting in inaccurate placement of the wafer or the dropping of the wafer resulting in a total loss of the wafer. See id., at lines 12-20. According to the inventors, the present invention provides a cooling stage for a semiconductor substrate which may be used as a wafer pedestal to provide improved cooling to the wafer and reduce the wafer movements on the pedestal. See id., pages 5 and 6. Discussion Rejection of Claim 12 under 35 U.S.C. § 112, second paragraph Appellants fail to present arguments traversing this ground of rejection. See examiner’s answer, Paper No. 14, mailed September 6, 2002, page 4, last paragraph and appeal brief (references to appellants’ “appeal brief” refer to the “REVISED APPEAL BRIEF”, Paper No. 13, filed May 20, 2002), page 2, second paragraph. Accordingly, we summarily affirm this ground of 4Page: Previous 1 2 3 4 5 6 7 8 9 10 NextLast modified: November 3, 2007