Ex Parte LEVINE et al - Page 5




          Appeal No. 1998-0936                                                        
          Application 08/369,011                                     Page 5           


          are simultaneously pulsed, and phase modulation is then used to             
          differentiate between the diodes at a receiver.  The examiner's             
          position (answer, page 6) is that the IRLEDs are individually and           
          sequentially pulsed because each of the diodes "have been                   
          drive[n] by a circuit (see figure 6) with their own drive                   
          signals, which are +90", 0, -90" square waves."                             
               Auerbach discloses (col. 3, lines 43-49) that “LEDs of the             
          handunit having respective fixed physical angular offsets from              
          the pointing axis of the remote control handunit are                        
          simultaneously energized with respective signals having                     
          corresponding fixed phase shifts from a 0" reference phase.”                
          Auerbach further discloses (figure 5 and col. 6, lines 28-52)               
          that IR transmission from the remote control is partitioned into            
          four principal intervals.  Signals transmitted during the synch             
          and phase-reference interval synchronize the receiver with the              
          transmitter.  In the Y-axis measurement interval, there is                  
          simultaneous energization of LEDS 401-406.  During the data                 
          measurement interval, a signal representative of the output of an           
          array of pushbutton switches is transmitted simultaneously by all           
          of the LEDs using the same energizing signal.  In the X-                    
          measurement interval there is a simultaneous energization of LEDs           
          401-404, 407, and 408.                                                      