Ex Parte Bissen et al - Page 9




          Appeal No. 2003-0771                                                        
          Application No. 09/031,666                                                  


          Krynytzky’s disclosure, can be translated into capabilities for a           
          complex pipeline system of the type utilized by Krynytzky, which            
          would reasonably appear to have different fluid flow concerns               
          from fire hoses.                                                            
               Since we have determined that the teachings and suggestions            
          found collectively in Krynytzky, Ronan, Williams and Thorton-               
          Trump would not have made the subject matter as a whole of                  
          independent claims 1, 13 and 17 obvious to one of ordinary skill            
          in the art at the time of appellants’ invention, we cannot                  
          sustain the examiner’s rejection under 35 U.S.C. § 103(a) of                
          those claims, or claims 2-12, 14-16 and 18-23 that depend                   
          therefrom.                                                                  

















                                          9                                           





Page:  Previous  1  2  3  4  5  6  7  8  9  10  11  Next 