Ex Parte Kafrawy et al - Page 9




                    Appeal No. 2004-0479                                                                                                                                  
                    Application No. 09/780,864                                                                                                                            


                    5. Cambron's Figure 2 shows an uninterrupted solid outside                                                                                            
                    perimeter line connecting hub 13 and blood-detecting chamber                                                                                          
                    14.                                                                                                                                                   
                    6. Cambron's Figure 2 shows within the passage way an                                                                                                 
                    uninterrupted solid inside perimeter line connecting hub 13                                                                                           
                    and blood-detecting chamber 14.                                                                                                                       
                    7. Cambron's Figure 2 does not show a horizontal line                                                                                                 
                    connecting the outside perimeter line and the inside perimeter                                                                                        
                    line at the interface between hub 13 and blood-detecting                                                                                              
                    chamber 14, but instead shows a solid material.                                                                                                       
                    8. Cambron's Figure 2 shows that the hub 13 and blood-                                                                                                
                    detecting chamber 14 have the same cross-hatching.                                                                                                    
                    9. Cambron's Figure 2 shows an uninterrupted solid outside                                                                                            
                    perimeter line connecting plug 20 and diaphragm 23.                                                                                                   
                    10. Cambron's Figure 2 shows an uninterrupted solid inside                                                                                            
                    perimeter line connecting plug 20 and diaphragm 23.                                                                                                   
                    11. Cambron's Figure 2 does not show a horizontal line                                                                                                
                    connecting the outside perimeter line and the inside perimeter                                                                                        
                    line at the interface between plug 20 and diaphragm 23, but                                                                                           
                    instead shows a solid material.                                                                                                                       