California Labor Code ARTICLE 4 - Structural Steel Framed Buildings

  • Section 7250.
    As used in this article “building” means any multifloor structural steel framed building more than two stories high in the course of construction.(Added by Stats....
  • Section 7251.
    As defined above, these provisions shall apply to buildings erected in tiers or stories and shall not apply to steel framed buildings having large open...
  • Section 7252.
    The derrick or working floor of every building shall be solidly decked over its entire surface except for access openings.(Added by Stats. 1970, Ch. 1498.)
  • Section 7253.
    There shall be a tight and substantial temporary floor within two floors below and directly under that portion of each tier of beams on which...
  • Section 7254.
    Temporary floors shall be wood planking of proper thickness, grade and span to carry the working load, but shall not be less than two inches...
  • Section 7255.
    Provision shall be made to secure temporary flooring against displacement by strong winds or other forces.(Added by Stats. 1970, Ch. 1498.)
  • Section 7256.
    Planks shall extend a minimum of 12 inches beyond centerline of their supports at each end.(Added by Stats. 1970, Ch. 1498.)
  • Section 7257.
    Wire mesh or plywood (exterior grade) shall be used to cover openings adjacent to columns where planks do not fit tightly.(Added by Stats. 1970, Ch.
  • Section 7258.
    Metal decking where used in lieu of wood planking shall be of equivalent strength and shall be laid tightly and secured to prevent movement.(Added by...
  • Section 7259.
    Floor planks that are temporarily removed for any reason whatsoever shall be replaced as soon as work requiring their removal is completed or the open...
  • Section 7260.
    Prior to removal of temporary floor plank, employees shall be instructed by assigned supervision the steps to be taken to perform the work safely and...
  • Section 7261.
    When gathering and stacking temporary floor plank on a lower floor, in preparation for transferring such plank for use on an upper working floor, the...
  • Section 7262.
    When gathering and stacking temporary floor planks from the last panel, the steel erector’s personnel assigned to such work shall be protected by safety belts...
  • Section 7263.
    The sequence of erection, bolting, temporary guying, riveting and welding shall be such as to maintain the stability of the structural frame at all times...
  • Section 7264.
    Where a building is being constructed in sections, each section constitutes a building as defined in Section 7250.(Added by Stats. 1970, Ch. 1498.)
  • Section 7265.
    Safety belts and nets shall be required in accordance with Article 24 (commencing with Section 1669) of subchapter 4 of Chapter 4 of Part 1...
  • Section 7266.
    No person shall proceed with any work assigned to or undertaken by him, or require or permit any other person to proceed with work assigned...
  • Section 7267.
    The Division of Occupational Safety and Health shall enforce this article.(Amended by Stats. 1980, Ch. 676.)