33. Bilstad's Figures 3A-3D are reproduced below: 14 - 16 FIG. 3A ED= 54 IDư FIG. 3B 101E::)=:o60 P" 1o_,J [ư 54 W. FIG. 3C FIG. 3D 34. Figures 3A - 3D shows separate components 10 and 12, each moving in a single direction towards the other. incorporated by reference. Tube 54 is preferably about 5 cin (2") from the area in which an active sterile field is desired and operates at about 60 KeV. Higher voltages may allow a greater gap, and a lower voltage might require a lesser gap. FIGURE 3A shows the pre-sterilized components 10, 12 arranged prior to connection. Tube 54 creates the spherical-shaped e-bearn field 60 having approximately a two-inch diameter. Other diameters of the sterile field are certainly possible, however manipulation of the joining of components requires very little space. Where a greater space is required, field 60 could be made larger by conventional methods. Referring to FIGURE 3B, the ends 14 of components 10, 12 are conveyed into the sterile e-beam field 60. While maintained within sphere 60, ends 14 of each component 10, 12 may be cut-off, as shown in FIGURE 3C, to create opened ends. The mechanism for opening these ends may be a mechanical blade, which may be held permanently within the e-beam field 60 to maintain its sterility, or any other suitable cutting or opening mechanism. FIGURE 3D shows that once the ends 14 are cut-off, the resulting open ends are connected together while still within the field 60. B. Ex. 2006, p. 7,11. 5-27.Page: Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NextLast modified: November 3, 2007