Ex Parte Kabeya et al - Page 8

                Appeal 2007-2421                                                                             
                Application 10/289,793                                                                       
                as anyone skilled in the art would have immediately understood that                          
                the CGL included submerged support rolls.  (Id. at 2).                                       

                11) Mr. Kawamura testifies that he did not even consider                                     
                eliminating the submerged support rolls from his device due to his                           
                belief that it would increase the number of defects on the metal strip.                      
                (Id.).                                                                                       

                            2.     Mr. Noboru Taguchi                                                        
                12) Mr. Taguchi testifies that he holds a Master of Engineering                              
                degree.  (Taguchi Declaration, p. 1).                                                        

                13) Mr. Taguchi testifies that he has spent over thirty (30) years                           
                working in the steel industry including working in a coated steel                            
                technology department.  (Id.).                                                               

                14) Mr. Taguchi states that he now holds a position as the Manager                           
                of the Sheet and Strip Business Planning Department of the JFE Steel                         
                Corporation.  (Id.).                                                                         

                15) Mr. Taguchi declares that when he read Kawamura he                                       
                understood that “submerged support rolls must be included in the                             
                system disclosed therein.”  (Id. at 2).                                                      

                16) Mr. Taguchi declares that all CGLs operating in Japan at the                             
                time of the invention were equipped with submerged support rolls.                            
                (Id.).                                                                                       