Ex Parte Suzuki et al - Page 18


                Appeal No. 2007-0464                                                                                                   
                Application 09/964,874                                                                                                 
                not disclose measuring temperature a number of times and taking responsive action based on the                         
                difference between the measured temperature and the measured temperature immediately                                   
                preceding the most recently measured temperature.  Answer at page 13, Lines 12-15.  For that                           
                feature of the claimed invention, the examiner relies on Kulakowski and alternatively on Takagi.                       
                        The examiner’s reading of Kulakowski is incorrect.  Kulakowski compares a measured                             
                temperature with a first threshold and also a second threshold.  There is no basis to read a                           
                threshold temperature to which a measured temperature is compared as itself a measured                                 
                temperature and one measured either at startup of the disk drive as is required by claim 24 or one                     
                measured immediately preceding the most recently measured temperature as is further specified                          
                in claim 25.  The portions of Kulakowski cited by the examiner do not describe either the first or                     
                the second threshold value as a measured temperature.                                                                  
                        Takagi, on the other hand, does disclose continual measurement of the temperature inside                       
                the optical disk drive near the optical head (FF. 32).  The measured values are transmitted to a                       
                control unit which continually determines a temperature change from the time the last control                          
                adjustment was made, and when that difference in temperature exceeds a predetermined value,                            
                steps are taken to make a further adjustment (FF. 33).                                                                 
                        The applicant argues that Takagi’s polling of the operating temperature is not the same as                     
                determining the difference between the most recently measured temperature and the measured                             
                temperature immediately preceding the most recently measured temperature.  The argument is                             
                misplaced.  Precise sameness is not the issue.  If it were, then certainly Takagi’s looking at the                     
                difference between the most recently measured temperature and the measured temperature at the                          
                time of the last control adjustment is not precisely the same as looking at the difference between                     
                the most recently measured temperature and the immediately preceding measured temperature.                             