Ex parte FOGAL - Page 8




            Appeal No. 2000-0949                                                                              
            Application No. 08/721,505                                                                        



              locating a bond site on the tip portion ofHoldgrafer discloses the bonding point to             
              the selected lead finger generally along the be a predetermined distance from the               
              longitudinal axis and spaced from a       edge, 25 or tip.  (See col. 5 lines 54-58             
              terminal edge of the selected lead finger and figure 3.)                                        
              by a predetermined distance; and                                                                
              bonding the fine bond wire to the selected Since the vision system of Holdgrafer is             
              lead finger substantially at the bond site.intended to be associate with a wire                  
                                                        bonding apparatus, the wire bonding                   
                                                        apparatus would bond the wire to the lead             
                                                        finger. (See col. 7, lines 19-32).                    


            Appellant’s specification discloses that determining and using the longitudinal axis of the       
            lead finger in wire bonding was well known.  In the "Background of the Invention" section,        
            Appellant states:                                                                                 
                         In general, such vision systems are adapted to sense the lateral                     
                   edges of the lead fingers and to teach a bond site in the middle of the lead               
                   finger somewhere along the longitudinal axis of the lead finger. There is,                 
                   however, no provision for precisely locating the bond site on a lead finger an             
                   exact distance from the tip of the lead finger. Typically, the bonding tool is             
                   programmed by an operator to move a set distance away from the bond pad                    
                   for placing the bond site along the longitudinal axis of a lead finger. This is            
                   not an accurate or consistent method for teaching a bond site location on a                
                   lead finger. In addition, this method of locating a bond site tends to use more            
                   bond wire than is necessary because the length of the bond wire is                         
                   consistently oversized.                                                                    
            (Emphasis added.) (See column 1, line 58- col. 2, line 3.)                                        